5-8 MS-2 CCD Reader User’s Manual
Interleaved 2 of 5
Interleaved 2 of 5
Check Character Status (Interleaved 2 of 5)
Check Character Output Status (Interleaved 2 of 5)
Usage: Interleaved 2 of 5 has been popular because it is the most dense symbology
for printing numeric characters less than 10 characters in length; however,
Microscan does not recommend this symbology for any new applications
because of inherent problems such as truncation.
Definition: A dense, contimuous, self-checking, numeric symbology. Characters are
paired together so that each character has five elements, two wide and
three narrow, representing numbers 0 through 9, with the bars representing
the first character and the interleaved spaces representing the second
character. (A check character is highly recommended).
Serial Cmd: <K472,status,check character status,check character output status,symbol
length #1,symbol length #2>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
Usage: This option is not typically used, but it can be enabled for additional security
in applications where the host requires redundant check character verification.
Definition: An error correcting routine in which the check character is added.
Serial Cmd: <K472,status,check character status,check character output status,symbol
length #1,symbol length #2>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
Definition: When enabled, a check character is sent along with the symbol data for
added data security.
Serial Cmd:
<
K472,
status,check character status,
check character output status
,symbol
length #1,symbol length #2>
Default: Disabled
Options: 0 = Disabled 1 = Enabled