5-4 MS-2 CCD Reader User’s Manual
Code 39
Code 39
Check Character Status (Code 39)
Check Character Output Status (Code 39)
Usage: Code 39 is the most widely used non-retail 1D symbology.
Definition: An alphanumeric symbology with unique start/stop code patterns, composed
of 9 black and white elements per character, 3 of which are wide.
Serial Cmd: <K470,status,check character status,check character output status,0,0,
minimum symbol length,full ASCII set>
Default: Enabled
Options: 0 = Disabled 1 = Enabled
Definition: When enabled, the reader will verify a Modulus 10 check character in order
to identify the decode as successful.
Serial Cmd: <K470,status,check character status,check character output status,
0,0,minimum symbol length,full ASCII set>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
Usage: Check Character Output Status, when added to the symbol, provides
additional data security.
Definition: When enabled, the check character is read and output along with the symbol
data. When disabled, symbol data is output without the check character.
Note: With Check Character Output Status and an External or Serial
trigger option enabled, an invalid check character calculation will cause a
No Read message to be transmitted at the end of the read cycle.
Serial Cmd: <K470,status,check character status,check character output status,
0,0,minimum symbol length,full ASCII set>
Default: Disabled
Options: 0 = Disabled 1 = Enabled