5-14 Quadrus EZ Reader User’s Manual
Bad/No Symbol Qualification
Dimension Mode (2D Symbology Qualification)
Disabled
Decoded messages are output, but no attempt to qualify symbols or output Bad or No
Symbol messages is undertaken.
Bad/No Symbol Output
Checks first for decodes. If no symbol is decoded, checks for symbol dimension. If both
Dimension 1 and Dimension 2 requirements are met, a Bad Symbol message is output. If
both are not met, outputs a No Symbol message.
Object Qualification
Checks first for matches to symbol dimension. If qualified, attempts to decode. If no
decodes are found within the specified read cycle parameters, outputs a Noread mes-
sage.
Enable Both
Same as Object Qualification, except that if neither Dimension 1 nor Dimension 2 quali-
fies, then a No Symbol message is output; if either Dimension 1 or Dimension 2 quali-
fies, then a Bad Symbol message is output.
Dimension 1 (2D Symbology Qualification)
Definition: Enables the searches for symbol Dimension 1 and Dimension 2.
Serial Cmd:
<K718,finder pattern status,symbol size status,symbol size 1,symbol size
2,symbol size tolerance,dimension mode,dimension 1,dimension 2,dimen-
sion tolerance,orientation mode,orientation value>
Default: Disabled
Options:
0 = Disabled
1 = Bad/no symbol output
2 = Object qualification
3 = Enable both
Definition:
Checks symbol dimension for a specified number of pixels. In the case of
rectangular symbols, checks the longer side.
Serial Cmd:
<K718,finder pattern status,symbol size status,symbol size 1,symbol size
2,symbol size tolerance,dimension mode,dimension 1,dimension 2,dimen-
sion tolerance,orientation mode,orientation value>
Default: 0
Options: 0 to 656 pixels