2-4 Quadrus EZ Reader User’s Manual
RS-232/422 Host Port
RS-232/422 Host Port
The host port can be configured with RS-232 and RS-422 connections.
Host Port Connections
These settings define the basic transmission speeds and digital standards that ensure
common formatting.
Baud Rate, Host Port
Parity, Host Port
Stop Bits, Host Port
Usage: Can be used to transfer data faster or to match host port settings.
Definition: The rate at which the reader and host transfer data back and forth.
Serial Cmd: <K100,baud rate,parity,stop bits,data bits>
Default: 115.2K
Options:
0 = 600 1 = 1200 2 = 2400
3 = 4800 4 = 9600 5 = 19.2K
6 = 38.4K 7 = 57.6K 8 = 115.2K
Usage: Only changed if necessary to match host setting.
Definition:
An error detection routine in which one data bit in each character is set to 1
or 0 so that the total number of 1 bits in the data field is even or odd.
Serial Cmd: <K100,baud rate,parity,stop bits,data bits>
Default: None
Options: 0 = None 1 = Even 2 = Odd
Usage: Only changed if necessary to match host setting.
Definition:
One or two bits added to the end of each character to indicate the end of
the character.
Serial Cmd: <K100,baud rate,parity,stop bits,data bits>
Default: One
Options: 0 = One 1 = Two