Quadrus EZ Reader User’s Manual 5-27
I/O Parameters
Trigger Image Mode
Last Capture
At the end of a triggered read cycle, the video output will be the last capture.
Good Read
At the end of a triggered read cycle, the video output will be the last good read capture.
Note: If a good read does not occur, there is no video output.
Noread
At the end of a triggered read cycle, the video output will be the last noread capture
Slide Show
At the end of a triggered read cycle, all of the captures taken in the read cycle will be
output at a rate of 350mS between captures. The last capture will be held for 700mS and
then the cycle will be repeated.
Note: This only functions in a triggered mode.
Selected Capture
At the end of a triggered read cycle, the video output will be the capture specified in the
Capture Number field.
Image Frame
Definition: Event which triggers a video output.
Serial Cmd: <K760,video output mode,trigger image mode,image frame>
Default: Last Capture
Options:
0 = Last Capture 1 = Good Read
2 = Noread 3 = Slide Show
4 = Selected Capture
Definition: Specifies the frame that will be output at the end of the read cycle.
Serial Cmd: <K760,video output mode,trigger image mode,image frame>
Default: 1
Options: 1 to 8