Quadrus EZ Reader User’s Manual 7-7
Matchcode
Match Length
Usage:
For example, if Match Length is set to 6 in a 10 character symbol, and
Match Start Position is set for 2, only the 2nd through 7th characters (from
left to right) will be compared.
Definition:
Defines the length of the character string that will be compared with that of
the master symbol when Match Start Position is set to 1 or greater. when
Match Start Position is set to 0, no comparison will occur.
Serial Cmd:
<K223,matchcode type,sequential matching,match start position,match
length,wild card character,sequence on noread,sequence on mismatch>
Default: 1
Options: 1 to 2710