
7-6 Quadrus EZ Reader User’s Manual
Match Start Position
Match Start Position
Note: Match Start Position must be set to 1 or greater to enable this feature. A 0 setting
will disable this feature.
Usage:
Match Start Position is useful in defining specific portions of a symbol for
comparisons. For example, if a symbol contains a part number, manufacturing
date, and lot code info but the user is only interested in the part number
information. With Match Start Position the reader can be set to only sort on
the part number and ignore the rest of the characters.
Definition:
Match Start Position determines the portions of symbols that will be
matched by defining the first character in the symbol (from left to right) that
will be compared with those of the master symbol, when Matchcode Type is
set to Enabled or Sequential.
Function:
For example, if Match Start Position is set to 3, the first 2 characters read
in the symbol will be ignored and only the 3rd and subsequent characters to
the right will be compared, up to the number of characters specified by
Match Length.
Serial Cmd:
<K223,matchcode type,sequential matching,match start position,match
length,wild card character,sequence on noread,sequence on mismatch>
Default: 0
Options: 0 to 2710
Comentarios a estos manuales