Quadrus EZ Reader User’s Manual 12-9
Utilities
Enter Master Symbol Data
Definition:
Allows you to enter master symbol data for a any enabled master symbol
index number (1 to 10), provided the total number of characters does not
exceed the specified maximum.
Serial Cmd: <K231,master symbol number,master symbol data>
Options
Enter data for 1 to 10 symbols (any combination of ASCII text up to the
specified maximum.
For example, to enter data for master symbol 9, after making certain that
master symbol database size is enabled for 9 or more symbols, send
<K231,9,data>.
Caution: If no data is entered, the existing data will be deleted.
ESP:
1. Open the Utilities menu.
2. Set the number of master symbols you want to create in Master Symbol
Database Size.
3. Double-click on each symbol number you want to setup and copy or
type in your data in the popup dialog and click OK.
4. When all your data has been enter, click on the button, Send Database
to the Reader.