5-46 Quadrus EZ Reader User’s Manual
Output 1 Parameters
Output on Axial Non-Uniformity
Output on Unused Error Correction
Symbol Contrast Threshold
Usage: Lets the user know if symbol quality is less than acceptable.
Definition:
If enabled, toggles Output 1 active when Axial Non-Uniformity Thresh-
old is met.
Serial Cmd:
<K800,output on symbol contrast,symbol contrast threshold,output on print
growth,print growth threshold,output on axial non-uniformity,axial non-
uniformity threshold,output on unused ecc,unused ecc threshold>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
Usage: Lets the user know if symbol quality is less than acceptable.
Definition: If enabled, toggles Output 1 when Unused ECC Threshold is met.
Serial Cmd:
<K800,Output on Symbol Contrast,Symbol Contrast Threshold,Output on
Print Growth,Print Growth Threshold,Output on Axial Non-Uniformity,Axial
Non-Uniformity Threshold,Output on Unused ECC,Unused ECC Thresh-
old>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
Usage: Lets the user set the acceptable level of symbol quality.
Definition: Conforms to ISO/IEC 15415 symbol quality grading (A,B,C,D).
Serial Cmd:
<K800,output on symbol contrast,symbol contrast threshold,output on
print growth,print growth threshold,output on axial non-uniformity,axial non-
uniformity threshold,output on unused ecc,unused ecc threshold>
Default: Grade C
Options:
0 = Grade A 2 = Grade C
1 = Grade B 3 = Grade D
Vista de pagina 161