5-60 QX Hawk Industrial Imager User Manual
Read Cycle
Store No Read Image
Image storage allows the user to store images from separate read cycles and has the
ability to retrieve them later. The number of available slots for storage depends on the
mode of operation. If functioning in the rapid capture mode the number of images available
to store is the maximum Number of Captures – the current setting for number of captures.
If the user is operating in a continuous capture mode then they can store up to the maximum
number of captures – 3.
Image Storage Type
Disabled / Clear
Upon selection, all saved images will be cleared, and the unit will not store images for later
retrieving.
Store on No Read
The unit will store an image upon exiting the read cycle that retrieved a later time. If multiple
captures are present during the duration of a read cycle the image stored will be the last
image processed for the read cycle. This image is stored in RAM and can be retrieved as
long as power is applied and the unit has not been reset via reset/save sequences. Other
commands that can initialize the storage RAM are ones that changed capture modes or
put the unit in a test capture mode.
Image Storage Mode
First Image
In this mode the image storage will store images until the available image memory has
been filled. At this point the unit will stop saving additional images. In this mode you will
always have the first images that were stored.
Last Image
In this mode the image storage will continue to store images after the available memory
has been filled by purging the oldest image in the storage memory. In this mode you will
always have the last images that were stored.