QX Hawk Industrial Imager User Manual 4-17
Setup
Open
Open removes minor light defects of dark cells by performing a Dilate function followed by
an Erode function.
Close
Close remove
V minor dark defects of lig
ht cells by performing an Erode function followed
by a
Dilate
function.
Operator Size
Operator Size determines the size of the area or “pixel neighborhood” (measured in pixels)
in which the morphological operation is being performed.
Small (3 pixels by 3 pixels)
Medium (5 pixels by 5 pixels)
Large (7 pixels by 7 pixels)