7-12 QX Hawk Industrial Imager User Manual
Master Database
Master Symbol Database Size
Master Symbol Database Size allows the user to select 1 to 10 master symbols for the
master symbol database.
Important: Since the total number of characters available for the master symbol database
is 3000, changes to the Master Symbol Database Size will re-allocate the number of
characters available for each master symbol and could cause existing master symbols to
be deleted (except master symbol # 1, unless it also exceeds the size limitation).
The table below specifies the maximum number of characters available to each symbol
according the number of master symbols defined, from 1 to 10.
Master Symbol
Number
Maximum
Characters
# 1 3000
# 2 1500
# 3 1000
# 4 750
# 5 600
# 6 500
# 7 428
# 8 375
# 9 333
# 10 300
Set Master Symbol
Database Size here.