QX Hawk Industrial Imager User Manual A-63
Appendices
Output 1 Parameters
Output On (Output 1 Parameters)
Output State (Output 1 Parameters)
Pulse Width (Output 1 Parameters)
Output Mode (Output 1 Parameters)
Output 2 Parameters
Output 3 Parameters
Serial Cmd:
<
K810,output on
,output state,pulse width,output mode>
Default: Mismatch or No Read
Options: 0 = Mismatch or No Read
1 = Match or Good Read
2 = Mismatch
3 = No Read
4 = Trend Analysis
5 = Symbol Quality
6 = Diagnostic Warning
7 = In Read Cycle
Serial Cmd:
<
K810,
output on,
output state
,pulse width,output mode>
Default: 0 = Normally Open
Options: 0 = Normally Open 1 = Normally Closed
Serial Cmd:
<
K810,
output on,output state,
pulse width
,output mode>
Default: 500
Options: 1 to 65535 (in 1 ms increments)
Serial Cmd:
<
K810,
output on,output state,pulse width,
output mode
>
Default: 0 = Pulse
Options: 0 = Pulse
1 = Latch Mode 1 (Unlatch Input 1 Pin)
2 = Latch Mode 2 (Unlatch Opposite Condition)
3 = Latch Mode 3 (Unlatch Re-Enter Read Cycle)
Serial Cmd:
<
K811,
output on,output state,pulse width,output mode>
Serial Cmd:
<
K812,
output on,output state,pulse width,output mode>
Comentarios a estos manuales