4-26 QX Hawk Industrial Imager User Manual
Configuration Database
Morphology Operation
Allows the user to select the method for processing captured images.
Parameter values for serial command <K255>:
0 – Disable
1 – Erode
2 – Dilate
3 – Open
4 – Close
Morphology Size
Determines the size of the area or “pixel neighborhood” (measured in pixels) in which the
morphological operation is being performed.
Parameter values for serial command <K255>:
3 – Small (3 pixels by 3 pixels)
5 – Medium (5 pixels by 5 pixels)
7 – Large (7 pixels by 7 pixels)
Top/Left/Height/Width (CMOS)
The image dimension settings can be applied as a Window of Interest or a Region of Interest
depending on the image dimension mode selected in the Database Mode command.
Top: 0 to (480 – height) Default: 0
Left: 0 to (752 – width) Default: 0
Height: 3 to (480 – top) Default: 480
Width: 8 to (752 – left) Default: 752
Top/Left/Height/Width (CCD)
The image dimension settings can be applied as a Window of Interest or a Region of Interest
depending on the image dimension mode selected in the Database Mode command.
Top: 0 to (960 – height) Default: 0
Left: 0 to (1280 – width) Default: 0
Height: 3 to (960 – top) Default: 960
Width: 8 to (1280 – left) Default: 1280