A-58 QX Hawk Industrial Imager User Manual
Serial Commands
Symbol Data Output
Symbol Data Output Status (Symbol Data Output)
When to Output Symbol Data (Symbol Data Output)
Symbology ID Output Status (Symbol Data Output)
Read Duration Output
Read Duration Output Status (Read Duration Output)
Read Duration Output Separator (Read Duration Output)
No Read Message
No Read Message Status (No Read Message)
No Read Message (No Read Message)
Serial Cmd: <K705,symbol data output status,when to output,symbology i.d. output
status>
Default: 3 = Good Read
Options: 0 = Disabled 1 = Match 2 = Mismatch
3 = Good Read
Serial Cmd: <K705,symbol data output status,when to output,symbology i.d. output
status>
Default: 0 = As Soon As Possible
Options: 0 = ASAP 1 = End of Read Cycle
Serial Cmd: <K705,symbol data output status,when to output,symbology ID output
status>
Default: 0 = Disabled
Options: 0 = Disabled 1 = Enabled (AIM-Defined ID) 2 = Readable ID
Serial Cmd: <K706,status,separator>
Default: 0 = Disabled
Options: 0 = Disabled 1 = Enabled
Serial Cmd: <K706,status,separator>
Default: Space (0x20)
Options: Any 7-bit ASCII character
Serial Cmd: <K714,No Read message status,No Read message>
Default: 1 = Enabled
Options: 0 = Disabled 1 = Enabled
Serial Cmd: <K714,no read message status,No Read message>
Default: NOREAD
Options: Any valid ASCII string up to 128 characters