Microscan QX Hawk Manual de usuario Pagina 314

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 460
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 313
7-32 QX Hawk Industrial Imager User Manual
Y-Modem Transfer Options
Y-Modem Transfer Options
Y-Modem Upload
<uy,path and image file name>
Note: There are only three scales available from the imager. The three scales are full,
quarter, and eighth. The Directory response will read out the image dimensions. To receive
the image, request to download by the reported dimensions. If quarter-scaled or eighth-scaled
images are required, then divide the dimensions by 4 or by 8 and request by the reduced
dimensions.
(1.) Directory
(None assumes root)
/ (Root Directory)
/saved (Saved Directory)
(2.) Image Status
Good/ (IP decoded a symbol)
No Read/ (IP did not decode a symbol)
Mismatch/ (IP decoded the wrong symbol)
Pending/ (Not run through IP)
(3.) Age
0 to n
n = Max Images (8 ? Max)
(4.) Image Name (Full-Scale)
1280 x 1024.bmp
1280 x 1024_gs.bmp
1280 x 1024.jpg
1280 x 1024_q(1-100).jpg
Valid Scales (Depends on Full Dimensions)
1280 x 1024 (Full)
320 x 256 (Quarter - divide by 4)
160 x 128 (Eighth - divide by 8)
(5.) Type
.bmp (Bitmap image - no loss of resolution)
.jpg (JPEG image - loss of resolution with compression)
JPEG Compression Quality (1-100%)
_q1.jpg
_q100.jpg
Examples: <uy,/saved/noread/2/320x256_gs.bmp> <uy,/saved/noread/2/320x256_q33.jpg>
Vista de pagina 313
1 2 ... 309 310 311 312 313 314 315 316 317 318 319 ... 459 460

Comentarios a estos manuales

Sin comentarios