Microscan QX Hawk Manual de usuario Pagina 386

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 460
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 385
A-70 QX Hawk Industrial Imager User Manual
Serial Commands
Intensity (Illumination, Standard QX Hawk)
Camera Settings (CMOS)
Shutter Speed (Camera Settings, CMOS)
Gain (Camera Settings, CMOS)
Camera Settings (CCD)
Shutter Speed (Camera Settings, CCD)
Gain (Camera Settings, CCD)
Sub-Sampling
Morphological Pre-Processing
Serial Cmd: <K539,mode,intensity>
Default: 2 = High
Options: 0 = Low 1 = Medium 2 = High
Serial Cmd: <K541,shutter speed,gain>
Default: 2,500
Options: 60 to 40,000
Serial Cmd: <K541,shutter speed,gain>
Default: 20
Options: 0 to 33
Serial Cmd: <K541,shutter speed,gain>
Default: 1,500
Options: 30 to 150,000
Serial Cmd: <K541,shutter speed,gain>
Default: 20
Options: 0 to 64
Serial Cmd: <K542,sub-sampling>
Default: 0 = Disabled
Options: 0 = Disabled 1 = 4:1 2 = 16:1
Serial Cmd: <K550,status>
Default: 0 = Disable
Options: 0 = Disable 1 = Enable
Vista de pagina 385
1 2 ... 381 382 383 384 385 386 387 388 389 390 391 ... 459 460

Comentarios a estos manuales

Sin comentarios