A-84 QX Hawk Industrial Imager User Manual
Serial Commands
<#k.> Display Kernel Firmware Build Number
<#p.> Display System Configuration File Build Number
<!> Display All Available Firmware Checksums
Firmware/Checksum <!a> Display Application Firmware Checksum
<!d> Display DSP Firmware Checksum
<!p> Display System Configuration File Checksum
<?> Imager Status Request
<K?> All Status Request
<K??> All Descriptor Request
Imager Status <K?#> All Range Request
<Knnn?> Single Status Request
<Knnn??> Single Descriptor Request
<Knnn?#> Single Range Request
<Knnnd> Single Command Default
<LEARN> Initiate Learn Operation
Learn <UNLEARN> Initiate Unlearn Operation
<LEARN?> Display Learn Status
<G> Store Next Decoded Symbol to Database Index 1
Master Database <Gn> Store Next Decoded Symbol to Database Index n
<NEWM> New Master Load Status
PDF Information <a1> Enable/Disable PDF Information
<C> Perform Decodes/Second Test
Read Rate <Cp> Perform Decode Percent Test
<J> Exit Decodes/Second and Decode Percent Tests
Reboot System <reboot> Cold Boot System from Boot Code
Static Validation <VAL> Perform Static Validation of Data Matrix Symbol
Targeting
<l1> Activate Targeting System (Standard QX Hawk only)
<l0>
De-activate Targeting System (Standard QX Hawk only)
Temperature <@TEMP> Display Current Image Sensor Temperature
Y-Modem Transfer
<uy,path and image file
name>
Y-Modem Upload
<dy,key> Y-Modem Download (Code)
Comentarios a estos manuales