5-118 QX Hawk Industrial Imager User Manual
I/O Parameters
Four Beeps
Hold down button until four beeps are heard.
Disabled
When set to Disabled, the associated button position will have no function associated with
it, and the position will be skipped over.
Read Rate
Read Rate is initiated when the associated button position is selected. Read Rate will
perform decodes/second and is the same as sending a <C> from ESP’s Terminal. To exit
Read Rate, quickly press and release the EZ Button.
Calibrate
Calibrate
is initiated when the associated button position is selected. To cancel Calibration
,
quickly press and release the EZ Button.
Save for Power-On (Default)
All imager settings will be saved to non-volatile memory to be recalled on power-on
whenever the associated button position is selected. This is the same as sending a <Z>
from ESP’s Terminal.
Load New Master
Functions in the same way as New Master Pin input whenever the associated button
position is selected.
Target System
When the imager reaches this position, the targeting pattern appears. The targeting pattern
remains illuminated even if a different position is subsequently selected until this position
selection is disabled. To turn the targeting pattern off, quickly press and release the EZ
Button.
Bar Code Configuration
Enables Bar Code Configuration Mode whenever the associated button position is
selected. When enabled, the imager can accept configuration commands from symbols.
To disable, quickly press and release the EZ Button.