QX Hawk Industrial Imager User Manual A-39
Appendices
Address (Protocol Selection)
Protocol Port (Protocol Selection)
External Data Routing
Mode (External Data Routing)
Destination Port (External Data Routing)
Serial Cmd: <K160,protocol,address,protocol port>
Default: 1
Options: 1 – 50
1 = Poll address 0x1C, select address 0x1D
2 = Poll address 0x1E, select address 0x1F
...
50 = Poll address 0x7E, select address 0x7F
Serial Cmd: <K160,protocol,address,protocol port>
Default: 0
Options: 0 – 1
0 = Main RS-232 on QX Hawk Connector A
1 = RS-422/485 on QX Hawk Connector B
Serial Cmd: <K161,mode,destination port,ambles to source,echo to source,output at
end of read cycle,output at ETX,output at timeout>
Default: 0 = Disabled
Options: 0 = Disabled
1 = Transparent
2 = Half Duplex
3 = Full Duplex
4 = Customized
Serial Cmd: <K161,mode,destination port,ambles to source,echo to source,output at
end of read cycle,output at ETX,output at timeout>
Default: 0 = RS-232 on QX Hawk Connector A
Options: 0 = RS-232 on QX Hawk Connector A
1 = RS-232 on QX Hawk Connector B
2 = RS-422 on QX Hawk Connector B
4 = Ethernet TCP Port 1
5 = Ethernet TCP Port 2
6 = EtherNet/IP