A-104 QX Hawk Industrial Imager User Manual
Using EtherNet/IP
Clear Read Cycle Report and Counters (16)
Trigger, Decode/Match, Mismatch, Noread, Decoded Data string, and Sequence. A transition
from 0 to 1 is similar to sending the commands <U><W><Y><O>, which clear the historical
read cycle counters. Also, the Sequence counter and Decoded Data string will go to 0.
Note that if this command is received while a read cycle is active, execution of the command
will be delayed until the read cycle has ended, and the read cycle’s information will probably
be lost.
Unlatch Outputs (17)
If any outputs are configured for “Unlatch on Input1”, a transition from 0 to 1 will unlatch
the output. See configuration commands K810-812. It is not necessary for Input 1 to be
enabled.
External Output Control
0 = open the output contact
1 = close the output contact
Note: Not operational at this time.
QX Hawk OUT Assembly 0xC7, 199 decimal: Serial Command
(OUT: PLC -> QX Hawk)
Accessible only by unconnected explicit message.
This assembly enables the PLC to send serial commands to the device, similar to a serial port.
Known Issues and Limitations
1. External Output Control has not been implemented yet.
2. There is currently no way to receive serial command responses back from the QX Hawk.
Bit # Pin Name
0Out1
1Out2
2Out3
3-31 Reserved
Field # Data Type
Size (# of Data
Type Elements
Field Name
0 U32 1 Length of Command String (Field 1)
1 U8 256 Command String