5-148 QX Hawk Industrial Imager User Manual
I/O Parameters
Output 3 Parameters
Output 3 has the same parameters and default settings as Output 1 and Output 2.
Note: If you are using a QX Hawk C-Mount and External Illumination Mode is enabled,
the parameters for Output On, Pulse Width, and Output Mode are ignored.
Output On
Output On provides discrete signalling to host software to control external devices such
as PLCs and relays. It is useful for routing, sorting, and to prevent mis-packaging and
mis-routing.
Sets the discrete output functions for specific user-selected conditions. Allows the user to
set the conditions under which an output (or outputs) will be activated.
Note: If Output On is set to Match or Mismatch, a transition (switching) will not occur
unless Matchcode Type is enabled and a master symbol is loaded into memory.
Mismatch or No Read
Activates discrete output when the data does not match that of the master symbol or the
symbol has not been decoded before the end of the read cycle.
Good Read / Match
Activates a discrete output when the symbol data matches the master symbol.
Note: To output on Good Read when Matchcode is not enabled, enable any output for
Match.
Mismatch
Activates a discrete output whenever the symbol data does not match that of the master symbol.
No Read
Activates a discrete output whenever the symbol data is not decoded before the end of the
read cycle.
Trend Analysis
Typically used when successful decodes are occurring but a discrete output is needed to
flag a trend in quality issues.
Activates discrete output when a trend analysis condition is met, depending on the trend
analysis option enabled.