QX Hawk Industrial Imager User Manual 4-31
Setup
Database Mode
Switch Mode
Selects the event that causes the imager to load the next entry from the database to current,
active settings. When timer/count expires and “Image Process Looping” is enabled the
next database entry that has a camera modification will be used.
Notes:
Capture event always occurs when the 1st database entry is used.
This setting has no effect in Rapid Capture mode.
Rapid Capture mode always operates in “Number of Frames” mode, with a “Frame Count” = 1.
Time
The imager will load the next entry from the database to current after a defined time interval.
The timer will start upon use of a database entry. In other words, if the timer expires during
a capture event, the timer will not start again until the database entry has been incremented
and the new entry has been loaded to current.
Number of Image Frames
Database index is incremented after the specified number of image frames have been
captured.
Frame Count/Time
Indicates the “Number of Frames” that will occur or the amount of “Time” that is required
before the imager will load the next database configuration. Timer resolution is 1ms.
Image Process Looping
This feature is useful for processing a captured image frame multiple times with different
Image Process/Decode parameters.
Disabled
An image is captured for every database configuration, regardless if a camera setting has
been modified.
Enabled
When a database configuration is loaded to current, and the Camera settings have not
changed from last capture event, a new image is not captured. But rather the last image
frame that was captured is re-processed with the new Image Processing/Decode configuration.
The one exception is with the 1st database index, a new image is always captured when
the 1st database configuration is used. When a camera setting has been modified from
one database setting to the next, a new image is captured. For example, if all database
entries contained the same camera setting values, but had different IP/Decode configurations,
the only time an image frame would be captured would be when the 1st database configuration
was used.