Chapter 5 Codes
MS-880 Industrial Long Range Scanner User’s Manual 5-21
5–Codes
Fixed Code Length Status (PDF417)
Fixed Code Length (PDF417)
Note: Fixed Code Length Status must be enabled for Fixed Code Length to take
effect.
Serial Cmd: <K476,status,raster sweeps before decode attempt,fixed code
length status,fixed code length>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
Definition: Specifies the exact number of characters the scanner will recognize.
Serial Cmd: <K476,status,raster sweeps before decode attempt,fixed code length
status,fixed code length>
Default: 10
Options: 1 to 2710