Microscan MS-4X Manual de usuario Pagina 183

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 312
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 182
Chapter 12 Outputs
MS-880 Industrial Long Range Scanner User’s Manual 12-5
12–Outputs
Bar Code Output
Note: Bar Code Output relates to data and should not to be confused with
Outputs 1, 2, and 3 listed in the Outputs Parameters which describe output states
and functions.
Bar Code Output Status
Note: Bar Code Output Status if set to Match or Mismatch will not take effect
unless Matchcode Type is enabled and a master label is loaded into memory.
Disabled
Match
Definition: Defines the conditions under which decoded bar code labels are trans-
mitted to the host.
Usage: Useful when the host needs bar code data only under certain conditions.
Serial Cmd: <K705,output status,when to output>
Default: Good Read
Options: 0 = Disabled
1 = Match
2 = Mismatch
3 = Good Read
Definition: When set to Disabled, the scanner will not transmit any data that is
generated during a read cycle (bar codes, noreads, etc.).
Usage: It is useful when an application only needs to use the discrete outputs
and can allow the scanner to do the decision-making. When Disabled,
the host does not need the bar code data and the communication lines
are used only for setup and status checks.
Definition: When set to Match, the scanner transmits bar code data whenever a
bar code matches a master label. However, if Matchcode Type is Dis-
abled, it transmits on any good read.
Note: A noread can still be transmitted if Enabled.
Usage: Match is used in an application that requires specific bar code informa-
tion and needs to sort, route or verify based on matching the specific
bar code data.
Vista de pagina 182
1 2 ... 178 179 180 181 182 183 184 185 186 187 188 ... 311 312

Comentarios a estos manuales

Sin comentarios