Pharma Code
5-28 MS-880 Industrial Long Range Scanner User’s Manual
5–Codes
Minimum Number of Bars (Pharma Code)
Bar Widths (Pharma Code)
Forward/Reverse Decoding Direction (Pharma Code)
Serial Cmd: <K477,status,fixed bar length status,fixed bar length,min. no. of
bars,
bar widths,fwd/rev>
Default: 4
Options: 4 to 16
Serial Cmd: <K477,status,fixed bar length status,fixed bar length,min. no. of bars,
bar widths,fwd/rev>
Default: Mixed
Options: 0 = Mixed
1 = Narrow
2 = Wide
Definition: Specifies the direction that a bar can be read.
Serial Cmd: <K477,status,fixed bar length status,fixed bar length,min. no. of bars,
bar widths,fwd/rev>
Default: Forward
Options: 0 = Forward
1 = Reverse