Optoelectric Database Modes
8-10 MS-880 Industrial Long Range Scanner User’s Manual
8–Optoelectrics
Number of Active Database Settings
Latch on Trigger
Definition: This value sets the number of configuration database settings (in Data-
base Index) that are active. If Control Trigger mode has been
selected, this setting is ignored.
Usage: Can be useful when certain settings that are needed in one application
are not needed in another and processing time is at a premium.
Serial Cmd: <K226,mode,# active database settings,latch on trigger,timer
value, control trigger 1,control trigger 2,control trigger 3>
Default: 1
Options: Any number from 1 to 7.
ESP
Definition: This feature is only used in Control Trigger mode. If enabled, the con-
figuration database settings selected at the start of a read cycle will
remain active during the entire read cycle. If Latch on Trigger is dis-
abled, depending on the control trigger inputs, the scanner’s optical
settings can change throughout the read cycle.
Note: When Control Trigger #3 is enabled, Latch on Trigger is also
enabled regardless of its previous setting.
Usage: Useful when only one database index is required for the application.
Serial Cmd: <K226,mode,# active database settings,latch on trigger,timer value,
control trigger 1,control trigger 2,control trigger 3>
Default: Enabled
Options: 0 = Disabled
1 = Enabled
ESP