Output 1
14-6 MS-880 Industrial Long Range Scanner User’s Manual
14–Discrete I/0
Noread
Tren d Anal ysis
Active State
Pulse Width
Definition: Activates a discrete output whenever the bar code data is not decoded
before the end of the read cycle.
Definition: Activates discrete output when a trend analysis condition is met,
depending on the trend analysis option enabled.
Usage: Typically used when a discrete indication of a low read quality condition
occurs.
Definition: Sets the active state of the discrete output.
Serial Cmd: <K720,output on,active state,pulse width,output mode,trend analysis
mode,trigger evaluation period,number to output on,reads per trigger
threshold>
Default: Normally Open
Options: 0 = Normally Closed
1 = Normally Open
Definition: Sets the time in 10 mS increments that the discrete output remains
active.
Serial Cmd: <K720,output on,active state,pulse width,output mode,trend analysis
mode,trigger evaluation period,number to output on,reads per trigger
threshold>
Default: 5 (.05 seconds). Corresponds to 50 mS displayed in the menu.
Options: 1 to 255 (0.01 to 2.55 seconds). Divide the number entered on the
command line by 100 for time in seconds.