Chapter 12 Outputs
MS-880 Industrial Long Range Scanner User’s Manual 12-7
12–Outputs
End of Read Cycle
Definition: Enabling End of Read Cycle means that bar code data does not get
sent to the host until the read cycle ends with a timeout or new trigger.
Usage: End of Read Cycle is useful in timing-based systems in which the host
is not ready to accept data at the time it is decoded.
Note: Whenever Quality Output is Enabled, outputs will always func-
tion in End Of Read Cycle mode.
Read cycle Duration
Start of read cycle
End of read cycle
This is when host
expects output
Host
activates trigger
Figure 12-1 Read Cycle