Operational Tips
MS-880 Industrial Long Range Scanner User’s Manual A-35
Appendices
Appendix N — Operational Tips
Do:
Check inputs (label speed, length, height, etc.) to ensure the desired number of
decodes per label.
For optimum decodes, mount scanner so that your labels pass through the center of
the depth-of-field (minimum/maximum range). You find the center by moving your
label in and out during a read rate test.
Avoid excessive tilt, pitch, and skew of the bar code label.
Check the bar code label for readability by doing a decode rate test. If there is any
question about the label's readability, contact your Microscan representative at
helpdesk@microscan.com.
After changing any parameter that might affect decode rate, repeat decode rate
test.
Clean the scanner window with a clean, dry Q-tip or cotton cloth on a regular basis.
Do Not:
Aim the scanner into direct light or sunlight.
Aim the scanner into an external object detector or other light-emitting device.
Obstruct the scanner window with mounting hardware or other objects.
Connect chassis of scanner and host to different ground potentials.
Operate the scanner in excessive temperature environments.