Vista de pagina 227
Lifetime Hours
15-10 MS-880 Industrial Long Range Scanner User’s Manual
15–Diagnostics
Lifetime Hours
A message can be defined that will be transmitted whenever the scanner’s elapsed
time clock exceeds the set hours threshold. The message repeats one time every 30
minutes.
Hours Threshold
Note: Hours entered are 1/10 of the actual hours.
Message
Definition: A user can set a time in hours that will cause a message to be sent
whenever the scanner’s run time exceeds this value.
The elapsed time is the time the scanner is powered up.
Usage: Useful for setting up a preventive maintenance program.
Serial Cmd: <K401,hours10,message>
Default: 2500 (actually 25,000 hours)
Options: 0 to 65534
Definition: A user can define message up to 10-characters that will be displayed
whenever the hours threshold is reached or exceeded.
Serial Cmd: <K401, hours10,message>
Default: SERVICE
Options: Any 1 to 10 character ASCII string except NUL, <, or >.