Microscan MS-4X Manual de usuario Pagina 229

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 312
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 228
Chapter 15 Diagnostics
MS-880 Industrial Long Range Scanner User’s Manual 15-11
15–Diagnostics
Present Ambient Temperature (deg. C)
(This command is READ ONLY.)
Note: When viewing the Present Operating Temperature, allow at least 20 min-
utes after startup for the scanner’s inside and outside temperatures to stabilize.
Definition: Close estimation of external temperature.
A thermal sensor on the main PCB measures the internal temperature
of the scanner. From this a case-differential constant is subtracted to
yield an estimated external temperature.
Usage: Indicates temperature of the environment immediately outside of the
scanner. Useful for setting Over Temperature Threshold and Under
Temperature Threshold.
Serial Cmd: Send: <K408?>
Returns <K408 degrees Celsius>.
Vista de pagina 228
1 2 ... 224 225 226 227 228 229 230 231 232 233 234 ... 311 312

Comentarios a estos manuales

Sin comentarios