Chapter 12 Outputs
MS-880 Industrial Long Range Scanner User’s Manual 12-9
12–Outputs
Control/Hex Output
Definition: Determines the response to an Serial Command Echo or status
request command.
When set to Control, two characters are transmitted to represent a
non-displayable character. For example, a carriage return will be shown
as the two characters: ^M.
When set to Hex, the output is the hex character.
Usage: Useful for viewing settings with binary characters when using serial
command on a terminal.
Serial Cmd: <K701,serial command echo status,serial command beep status,con-
trol/hex output>
Default: Control
Options: 0 = Control 1 = Hex