Chapter 17 Utilities
MS-880 Industrial Long Range Scanner User’s Manual 17-11
17–Utilities
Enter Percent PDF Read Rate Test
Sending <CPDF> instructs the scanner to transmit the number of decodes per sec-
ond on the full PDF label. This test includes both capture and decode and translation
time. Note that the output format of the data is done as a running average of
750 mS windows. This means that you can remove the label from the view of the
scanner and it will continue to transmit some history of the label for a few outputs.
End Read Rate Test
Sending <J> ends both the Percent test and the Decodes/Second test for both
single and multi-label.
Enable PDF Information
Sending the <a1> check box will cause PDF417 symbology data to be prefaced with
information consisting of error correction level, number of rows, number of columns,
number of informative code words and the number of data characters.
Explanation of above PDF Info sample of a PDF417:
Level = 5 tells you that the error correction level is level 5. There are 13 rows and 6
columns. There are 14 info code words, and 16 characters in the data.
This feature can be disabled by using the exit read rate command <J>.