Chapter 8 Optoelectrics
MS-880 Industrial Long Range Scanner User’s Manual 8-5
8–Optoelectrics
Optoelectric Database Modes
Disabled Mode
Definition: A database index of up to seven pre-defined optical indexes of set-
tings defining focus, gain, and tracking can be accessed and applied
in the following modes:
1. by a timer in which all settings cycle throughout the time dura-
tion
2. by an automatic search for the best database index
3. by a combination of up to three control trigger inputs to dynam-
ically select the optimum database index
The index settings can also be saved and recalled selectively, or
reviewed with a Request Database Settings command.
Usage: Useful where different symbol types, sizes, qualities or distances
require more that one optical setup (focus, gain, and tracking) for
dynamic optical changes.
ESP:
Serial Cmd: <K226,mode,# active database settings,latch on trigger,timer
value, control trigger 1,control trigger 2,control trigger 3>
Default: Disabled
Options: 0 = Disabled
1 = Control Trigger
2 = Automatic/static mode
3 = Timer
Definition: When disabled, the scanner uses the current scanner configuration
settings.
Serial Cmd: <K226,mode,# active database settings,latch on trigger,timer value,
control trigger 1,control trigger 2,control trigger 3>