EZ Match User Manual
5-7
Calibration
Disabled
When this feature is disabled, the Window of Interest is not modified after the calibration
process is complete.
Row and Column
If the calibration process is successful, the Window of Interest will be modified to frame the
symbol as well as an additional margin area around the symbol, determined by the WOI
Margin parameter. Refer to the diagram below:
Column
If the calibration process is successful, the Window of Interest columns will be modified to
vertically frame the symbol, plus an additional margin area around the symbol, determined
by the WOI Margin parameter. Refer to the diagram below:
Row
I
f the calibration process is successful, the Window of Interest rows will be modified to horizontally
frame the symbol, plus an additional margin area around the symbol, determined by the
WOI
Margin
parameter. Refer to the diagram below: