Microscan EZ Match Imager Manual de usuario Pagina 294

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 431
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 293
11-24
EZ Match User Manual
Image Processing Timeout
Image Processing Timeout
Notes:
The timeout period does not include capture time.
If a timeout occurs during processing and no symbols in the field of view have been
decoded, the image will be recorded as a No Read. For this reason, a longer
timeout
sh
ould be tried to ensure that the symbol is decoded successfully.
Usage: Useful in higher speed applications where image processing time is long
enough that not all captures have an opportunity to be processed.
Definition: Specifies the maximum amount of time to process a captured image.
When the timeout expires, the image processing is aborted. This timeout
works in both Rapid Capture and Continuous Capture modes, as well
as with the IP Database.
Serial Cmd: <K245,image processing timeout>
Default: 5,000 ms (5 sec.)
Options: 1 to 65535 (in 1ms increments)