EZ Match User Manual
6-5
Read Cycle
Multisymbol
Number of Symbols
Usage: Multisymbol is commonly used in shipping applications where a shipping
symbol contains individual symbols for part number, quantity, etc. This
feature allows on trigger to pick up all the symbols.
Definition: Multisymbol allows the user to define up to 100 symbols that can be read
in a single read cycle.
Conditions: The following conditions apply:
Each symbol must be different to be read, unless in
Rapid Capture
Mode, configured for “triggered capture”.
The maximum number of characters in a read cycle is 3,000 for
all
symbols.
All No Read messages are posted at the end of the data string, un
less
output
filtering is enabled.
If more than one symbol is within the field of view at the same time,
symb
ol data may not be displayed in the order of appearance.
If
Matchcode Type
is set to
Sequential
or if
Trigger
is set to
Continuous
Re
ad 1 Output, the imager will behave as if Number of Symbols
were
set
to 1, regardless of the user-defined configuration.
Definition: This parameter has no function when a Multi-Operation read cycle is
active. Each operation index (1 through 3) requires one qualified output for
each active operation.
Example: If tube and cap detection are both enabled for operation index 1,
the required number of symbols for that index would be 2.
Important: The same symbol, tube, or cap can be processed and qualified
by two different operations in the same read cycle.
Serial Cmd: <K222,number of symbols, multisymbol separator>
Default: 1
Options: 1 to 100