EZ Match User Manual
8-37
I/O Parameters
ISO/IEC 16022 Symbol Quality Output 1
Note: Output On under Output 1 Parameters must be set to Symbol Quality (as shown
below) for this output to function.
Under Output 1 Parameters, expand the Symbol Quality (ISO/IEC 16022) line.
Output on Symbol Contrast
Output on Print Growth
Usage: Lets the user know if symbol quality is less than acceptable.
Definition: If enabled, toggles Output 1 to an active state when Symbol Contrast
Threshold is met.
Serial Cmd:
<
K800,output on symbol contrast
,symbol contrast threshold,output on print
growth,print growth threshold,output on axial non-uniformity,axial non-uniformity
threshold,output on unused ECC,unused ECC threshold>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
Usage: Lets the user know if symbol quality is less than acceptable.
Definition:
If enabled, toggles
Output 1
to an active state when
Print Growth Threshold
is met.
Serial Cmd:
<
K800,
output on symbol contrast,symbol contrast threshold,
output on print
growth
,print growth threshold,output on axial non-uniformity,axial non-uniformity
threshold,output on unused ECC,unused ECC threshold>
Default: Disabled
Options: 0 = Disabled 1 = Enabled