Microscan EZ Match Imager Manual de usuario Pagina 129

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 431
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 128
EZ Match User Manual
6-7
Read Cycle
Trigger Mode and Duration
Trigger
Note: When calibrating the imager or testing Read Rate, the current trigger setting will be
disregarded.
Trigger Mode
Continuous Read
Definition: The event that initiates the read cycle.
Serial Cmd: <K200,trigger mode,trigger filter duration>
Default: Continuous Read
Options: 0 = Continuous Read
1 = Continuous Read 1 Output
2 = External Level
3 = External Edge
4 = Serial Data
5 = Serial Data and Edge
Usage: Continuous Read is useful in testing symbol readability or reader functions.
It is not recommended for normal operations.
Definition: In Continuous Read, trigger input options are disabled, the imager is
always in the read cycle, and it will attempt to decode and transmit every
capture. If a single symbol stays within read range for multiple read cycles,
its data will be transmitted repeatedly until it leaves the read range.
The imager sends replies to serial commands that require responses when
symbol data is transmitted, or read cycle timeout is enabled and a timeout
occurs and at least one captured image has been processed. Depending
on the combination of enabled symbologies and the Threshold Mode setting,
the imager may take longer than the timeout to process a captured image.
Note: When to Output
and
No Read
options have no affect on
Continuous
Read.
Serial Cmd: <K200,0>