8-29
I/O Parameters
EZ Button Modes
Disabled
When set to disabled, the associated button position will have no function associated with
it, and the position will be skipped over.
Read Rate
Read Rate will be initiated when the associated button position is selected. Read Rate will
perform decodes/second and is the same as sending a <C> from the terminal. To exit
Read Rate Mode quickly press and release the EZ Button.
Calibration
Calibration will be initiated when the associated button position is selected. To abort calibration
,
quickly press and release the EZ Button.
Save for Power-On
All imager settings will be saved to non-volatile memory to be recalled on power-on
whenever the associated button position is selected. This is the same as sending a <Z>
from the terminal.
Load New Master
Functions in the same way as new master pin input whenever the associated button
position is selected. The new master pin’s Consecutive Decode requirement holds true
for this function.
Usage: Useful for performing multiple, repetitive tasks at the work site.
Definition:
Allows the user to program each of the EZ Button’s 4 positions from a selection
of 10 modes.
Serial Cmd: <K771,single beep,two beeps,three beeps,four beeps>
Options: 0 = Disabled 1 = Enabled
Single Beep Two Beeps Three Beeps Four Beeps
0 = Disabled 0 = Disabled 0 = Disabled 0 = Disabled
1 = Read Rate 1 = Read Rate 1 = Read Rate 1 = Read Rate
2 = Calibration 2 = Calibration 2 = Calibration 2 = Calibration
3 = Save for Power-On 3 = Save for Power-On 3 = Save for Power-On 3 = Save for Power-On
4 = Unused 4 = Unused 4 = Unused 4 = Unused
5 = Load New Master 5 = Load New Master 5 = Load New Master 5 = Load New Master
6 = Unused 6 = Unused 6 = Unused 6 = Unused
7 = Target System 7 = Target System 7 = Target System 7 = Target System
8 = Unused 8 = Unused 8 = Unused 8 = Unused
9 = Bar Code Config. 9 = Bar Code Config. 9 = Bar Code Config. 9 = Bar Code Config.
10 = Tube/Cap Learn 10 = Tube/Cap Learn 10 = Tube/Cap Learn 10 = Tube/Cap Learn