EZ Match User Manual
6-19
Read Cycle
Number of Captures
Note: The range of maximum number of captures is dynamic. This range is
dependent on the maximum image size in the system. A full-size image
(1280 x 1024) reduces the maximum number of images to 6. The smaller
the image size, the greater the maximum number of captures. Once the
image size is reduced to small enough dimensions, the maximum number
of captures will be capped at 64.
If a user enters a maximum capture value greater than that allowed, the
value will be limited to the number of system images. This command also
affects the number of stored images allowed in the system. If the maximum
number of captures is selected, the number of stored images allowed will be
0
.
Note: Number of Captures specifies the maximum number of captures as
it pertains to a Multi-Operation read cycle. When configured to switch
operations on a frame count or timeout, the total number of captures cannot
exceed this maximum value.
When configured to switch operations on a specified frame count and the
operation completes before this maximum value is reached, the image
frame count will increase automatically to match the frame switch count.
This maintains image frame and timeout consistency for each operation
index.
Rapid Capture Mode
Usage:
Number of Captures
is used to specify the number of captures to be processed
in Rapid Capture Mode.
Definition: Sets the total number of captures that are processed during a read cycle in
Rapid Capture Mode. This feature is used in conjunction with Capture
Timing parameters to specify the capture sequence of a rapid capture read
cycle.
Serial Cmd:
<
K241,
capture mode,
number of captures
,rapid capture mode,pre-processing>
Default: 1
Options: 1 to 64
Definition: In Rapid Capture Mode, one or multiple captures (as many as 32) can be
taken at an interval specified by the time-between-captures parameter. In
this mode, the only limiting time factor is integration and transfer timing.
Serial Cmd:
<
K241,
capture mode,number of captures,
rapid capture mode
,pre-processing>
Default: Timed Capture
Options:
0 = Timed Capture
1 = Triggered Capture