5-10
EZ Match User Manual
Calibration by ESP
Calibration by ESP
ESP’s Calibration view incorporates all the functionality of the <K529> (Calibration
Options) command in a single easy-to-use, intuitive interface. This calibration process
allows the user much finer control of individual parameters than the calibration routine in
EZ Mode or on the Video tab.
Before / During Calibration
Before and After tabs give the user an authentic
representation of the difference in what the imager
“sees” before and after the calibration routine.
Determines the
amount of time
and effort the
imager will spend
attempting to
decode a symbol
for each parameter
configuration.
(Low, Medium,
High, Definable).
Focus, Shutter,
Gain, and Image
Quality values
are all tracked in
real-time during
the calibration
process.
Initiates the
calibration
routine.
Cancels the
calibration
process, if
necessary.
The Window of Interest section of the Calibration interface allows the user to make precise adjustments
to WOI Framing, WOI Margin (in pixels), and the scan height of the straight-line image (in pixels).
Dropdown menu of 1D and 2D symbologies, and a check
box for enabling or disabling Composite symbologies.
Gain and Shutter Speed
are configurable in the
Calibration interface.