A-10
EZ Match User Manual
Communication Protocol Commands
No Read Message <K714,status,message>
Bad Symbol Message <K715,[unused],message>
No Symbol Message <K716,[unused],message>
1D/Stacked Symbology Qualification
<K717,minimum number of bars,minimum number of qualified
scan lines,start/stop status>
2D Symbology Qualification
<K718,finder pattern status,symbol size status,symbol size
1,symbol size 2,symbol size tolerance,dimension status,dimension
1,dimension 2,dimension tolerance,orientation status,orientation
value>
Frame Information <K734,output frame number,output coordinates>
LED Configuration <K737,LED mode,ISO/IEC 16022 grade>
Image Output
<K739,image output mode,communication port,file format,JPEG
quality>
Target/Flood LEDs
<K750,green flash LED status,target pattern LED status,green
flash duration>
EZ Trax Output
<K757,status,comm port,image mode,image format,JPEG quality,
object info output,grade output,color>
Database Identifier Output <K759,status,separator>
EZ Button
<
K770,
global status,default on power-on,load IP database
,save for
power-on>
EZ Button Modes <K771,single beep,two beeps,three beeps,four beeps>
Trend Analysis Output 1
<K780,trend analysis mode,trigger evaluation period,number to
output
on,
decodes/trigger threshold
>
Trend Analysis Output 2
<K781,trend analysis mode,trigger evaluation period,number to
output
on
,
decodes/trigger threshold
>
Trend Analysis Output 3
<K782,trend analysis mode,trigger evaluation period,number to
output
on,
decodes/trigger threshold
>
Diagnostic Output 1 <K790,unused 1,service unit>
Diagnostic Output 2 <K791,unused 1,service unit>
Diagnostic Output 3 <K792,unused 1,service unit>
ISO/IEC 16022 Symbol Quality Output 1
<
K800,
output on symbol contrast,symbol contrast threshold,output
on print growth,print growth threshold,output on axial non-uniformity
,
axial non-uniformity threshold,output on unused ECC, unused ECC
threshold>
ISO/IEC 16022 Symbol Quality Output 2
<
K801,
output on symbol contrast,symbol contrast threshold,output
on print growth,print growth threshold,output on axial non-uniformity
,
axial non-uniformity threshold,output on unused ECC, unused ECC
threshold>
ISO/IEC 16022 Symbol Quality Output 3
<
K802,
output on symbol contrast,symbol contrast threshold,output
on print growth,print growth threshold,output on axial non-uniformity
,
axial non-uniformity threshold,output on unused ECC, unused ECC
threshold>
Configurable Output 1 <K810,output on,output state,pulse width,output mode>
Configurable Output 2 <K811,output on,output state,pulse width,output mode>
Configurable Output 3 <K812,output on,output state,pulse width,output mode>
Tube/Cap Detection Output 1 <K860,mode,output on>
Tube/Cap Detection Output 2 <K861,mode,output on>
Comentarios a estos manuales