8-42
EZ Match User Manual
Tube/Cap Detection Output 1
Output On
*Important: There is no “Unknown” condition for Tube Detection. “Unknown” is not a valid
s
election for Output On if Detection Mode is set to Tube Detection.
Presence
Based on the mode selected (Tube Detection or Cap Detection), the output will be
asserted if the read cycle results in a Presence condition.
Absence
Based on the mode selected (Tube Detection or Cap Detection), the output will be
asserted if the read cycle results in an Absence condition.
Unknown
Since there is no “Tube Unknown” condition, the output will be asserted if the read cycle
results in an
Absence
condition and if the Tube/Cap Detection mode is set to Tube Detection.
If Tube/Cap Detection mode is set to Cap Detection, the Unknown condition will output
normally.
Definition: Output On selects the type of condition in which to output.
Serial Cmd: <K860,mode,output on>
Default: Presence
Options: 0 = Presence 1 = Absence 2 = Unknown*