Microscan EZ Match Imager Manual de usuario Pagina 290

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 431
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 289
11-20
EZ Match User Manual
IP Threshold
Cycle Max
Cycle Step
Adaptive Contrast Percent
Definition: Ending value of the cycle mode.
Serial Cmd: <K512,threshold mode,threshold value,cycle min,cycle max,cycle step,
adaptive contrast percent>
Default: 255
Options: 0 to 255
Important: Cycle Max must be a greater numerical value than Cycle Min.
Definition: The numerical value of a single cycle mode increment.
Serial Cmd: <K512,threshold mode,threshold value,cycle min,cycle max,cycle
step,adaptive contrast percent>
Default: 10
Options: 0 to 255
Definition: A percentage value that adjusts the adaptive threshold map; useful in
decoding underprinted or overprinted symbols.
Example: If an adaptive contrast value of 110 is set, then the adaptive
threshold will be 110% of the original contrast values.
Serial Cmd: <K512,threshold mode,threshold value,cycle min,cycle max,cycle step,
adaptive contrast percent>
Default: 100
Options: 1 to 200 (percent)
Vista de pagina 289
1 2 ... 285 286 287 288 289 290 291 292 293 294 295 ... 430 431

Comentarios a estos manuales

Sin comentarios