Microscan EZ Match Imager Manual de usuario Pagina 135

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 431
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 134
EZ Match User Manual
6-13
Read Cycle
Serial Trigger
Serial Trigger Character (Delimited)
Note: Serial Data or Serial Data and Edge triggering mode must be
enabled for Serial Trigger Character to take effect.
Important: The ASCII characters <, >, and , can only be entered as hex
pairs:
For <: <K201h,3C>
For >: <K201h,3E>
For , : <K201h,2C>
See ASCII Character Entry Modifier on page 4-33 for a detailed explanation
of how to enter ASCII characters as hex values.
Usage: Allows the user to define the trigger character and delimiters that start
and stop the read cycle.
Definition: A serial trigger is considered an online host command and requires the
same command format as all host commands. It must be entered within
angle bracket delimiters < > or, in the case of non-delimited triggers, it must
define individual start and stop characters.
Usage: Allows the user to define the trigger character that initiates the read cycle.
Definition: A single ASCII host serial trigger character that initiates the read cycle.
A delimited trigger character is one that either starts or ends the read cycle
and is enclosed by delimiters such as < >.
Serial Cmd: <K201,serial trigger character>
Default: Space bar
Options: Any single ASCII character, including control characters, except NUL (00 in
hex), an existing host command character, or an on-line protocol character.
Control characters entered on the command line are displayed in the menu
as mnemonic characters.
Vista de pagina 134