8-28
EZ Match User Manual
EZ Button
Default on Power-On
Load IP Database
Save for Power-On
Definition: When enabled, if the EZ Button is held down on power-on the imager will
default to customer defaults and save for power-on. This is the same as
sending a <Zrc> command.
Serial Cmd: <K770,global status,default on power-on,load IP database,save for
power-on>
Default: Enabled
Options: 0 = Disabled 1 = Enabled
Definition: Allows the user to load the IP Database with calibration results. When the
user performs a calibration using the EZ Button, all the database entries are
moved down one index and the results of the calibration are saved to
index 1. The results will be saved as current settings as well.
Serial Cmd: <K770,global status,default on power-on,load IP database,save for
power-on>
Default: Enabled
Options: 0 = Disabled 1 = Enabled
Definition: If enabled, after calibration is complete, all parameters will be saved for
power-on.
Serial Cmd: <K770,global status,default on power-on,load IP database,save for
power-on>
Default: Disabled
Options: 0 = Disabled 1 = Enabled